Acta bioquím. clín. latinoam ; 53(4): 487-497, dic. 2019. ilus, graf, tab
Article in English | LILACS | ID: biblio-1124026

ABSTRACT

Equivalence of results among laboratories is a major mission for medical laboratories. In the Netherlands, medical laboratories only use homogenous, commercial for general chemistry analytes, whereas in Argentina heterogenous, home brew test applications are common. The effect of this practice difference on test accuracy is studied using key features of the accuracy-based EQA program of the Netherlands. Six frozen, human-based, commutable poolsera, covering the (patho) physiological measuring range for 17 general chemistry analytes, were assayed by ~75 Argentinian labs and ~200 Dutch laboratories in 2014. After removal of outliers, harmonization status among laboratories was evaluated by calculating overall mean interlaboratory coefficients of variation (CVs, %) per analyte and per country for all 6 levels. Evenso, standardization status was evaluated after removal of outliers by calculating overall mean recoveries (%) as compared to the assigned target values per analyte per country for all 6 levels. Absolute median biases were compared to (minimal/desirable) biases derived from biological variation criteria. For serum enzymes interlaboratory CVs in the Argentinian laboratories ranged between 10 and 22%, as compared to 3-6% in the Netherlands. For serum uric acid, creatinine, glucose and total protein, interlaboratory CVs varied between 4.3 and 13.1% in Argentinian labs, as compared to <3.5% in the Netherlands. For serum electrolytes, interlaboratory CVs ranged between 1.8 and 3.8% for Na+; 2.9-5.8% for Cl-; 3.8-7.5% for K+; 9.4-10.4% for Ca2+ and 16.2-22.3% for Mg2+ as compared to ≤2% (Na+, K+, Cl-, Ca2+) and ≤3% (Mg2+) in the Netherlands. Mean recoveries in Argentinian laboratories for e.g. serum creatinine, glucose, CK, Ca2+ and Na+ were 95-119%; 95-104%; 98-102%; 98-102% and 96-100% respectively, whereas min-max recovery ranges were 65-155%; 58-126%; 47-132%; 66-132% and 85-115%. In the Netherlands, absolute mean recoveries were overall 98.9% with a SD of 2.0%. Median biases in Argentinian laboratories ranged from -2.9 to 18.2%; -3.1 - 2.6%; -3.3 - 0.5%; -1.1 - 3.8% and -4.3-0% for serum creatinine, glucose, CK, Ca2+ and Na+. In the Netherlands overall mean/median biases were 1.1% (SD=2.0%). Exchange of commutable, value- assigned EQA-materials was helpful for studying the harmonization and standardization status of medical tests in Argentina, and for revealing the future harmonization and standardization potential. The results clearly demonstrate that metrological traceability of test results in Argentina is on average in line with what is expected; yet, the spreading among laboratories is far too high and should be improved.


La equivalencia de resultados entre laboratorios es una mision importante para los laboratorios medicos. En los Paises Bajos, los laboratorios medicos solo usan aplicaciones comerciales homogeneas, regulatoriamente aprobadas (CE-IVD) para analitos quimicos, mientras que en la Argentina son comunes las aplicaciones heterogeneas caseras. El efecto de esta diferencia practica en la precision de la prueba se estudia utilizando caracteristicas clave del programa EQA, basado en la precision, de los Paises Bajos. Se ensayaron seis pools de sueros, congelados, de origen humano, conmutables, que cubrian el rango de medidas (pato)fisiologicas para 17 analitos de quimica clinica. Estos analitos de quimica clinica fueron analizados por ~75 laboratorios argentinos y ~200 laboratorios holandeses en 2014. Despues de eliminar los valores atipicos, el estado de armonizacion entre los laboratorios fue evaluado calculando los coeficientes de variacion interlaboratorios medios globales (CV%) por analito y por pais para los 6 niveles. No obstante, el estado de estandarizacion se evaluo despues de la eliminacion de valores atipicos mediante el calculo de recuperaciones medias generales (%) en comparacion con los valores asignados por analito por pais para los 6 niveles. Los sesgos medios absolutos se compararon con los sesgos (minimos / deseables) derivados de los criterios de variacion biologica. Para enzimas sericas los CV interlaboratorio en los laboratorios argentinos oscilaron entre 10 y 22%, en comparacion con 3-6% en los Paises Bajos. Para el acido urico serico, creatinina, glucosa y proteinas totales, los CV entre laboratorios variaron entre 4,3 y 13,1% en los laboratorios argentinos, en comparacion con <3,5% en los Paises Bajos. Para los electrolitos sericos, los CV interlaboratorios oscilaron entre 1,8 y 3,8% para Na+; 2,9-5,8% para Cl-; 3,8-7,5% para K+; 9,4-10,4% para Ca2+ y 16,2-22,3% para Mg2+ en comparacion a ≤2% (Na+, K+, Cl-, Ca2+) y ≤3% (Mg2+) en los Paises Bajos. Las recuperaciones medias en laboratorios argentinos para, p.ej. la creatinina serica, glucosa, CK, Ca2+ y Na+ fueron 95-119%; 95-104%; 98-102%; 98-102% y 96-100% respectivamente, mientras que los rangos de recuperacion min-max fueron 65-155%; 58-126%; 47-132%; 66-132% y 85-115%. En los Paises Bajos, las recuperaciones medias absolutas fueron en general del 98,9% con una desviacion estandar (DE) del 2,0%. La mediana de los sesgos medios de los laboratorios argentinos oscilo entre -2,9 y 18,2%; -3,1 - 2,6%; -3,3 - 0,5%; -1,1 - 3,8% y -4,3-0% para creatinina serica, glucosa, CK, Ca2+ y Na+. En los Paises Bajos, las medias / medianas en general fueron de 1,1% (DE=2,0%). El intercambio de los valores asignados a los materiales EQA, conmutables fue de gran ayuda para la armonizacion y estandarizacion de los ensayos medicos en la Argentina y para revelar el potencial futuro de armonizacion y estandarizacion. Estos resultados claramente demuestran que la trazabilidad metrologica de los resultados de las pruebas en la Argentina esta, en promedio, de acuerdo con lo esperable; sin embargo, la dispersion entre laboratorios es muy grande y deberia ser mejorada.


A equivalencia de resultados entre laboratorios e uma missao importante para os laboratorios medicos. Nos Paises Baixos, os laboratorios medicos so utilizam aplicacoes comerciais homogeneas, aprovadas por regulacoes (CE-IVD) para analitos quimicos, ao passo que na Argentina sao comuns as aplicacoes heterogeneas caseiras. O efeito desta diferenca pratica na exatidao do teste e estudado utilizando caracteristicas essenciais do programa EQA, dos Paises Baixos, baseado na exatidao. Foram ensaiados seis pools de soros, congelados, de origem humana, comutaveis, que abrangiam a faixa de medidas (pato)fisiologicas para 17 analitos quimicos gerais. Esses analitos quimicos foram analisados por ~75 laboratorios argentinos e ~200 laboratorios holandeses em 2014. Apos eliminar os valores atipicos, o estado de harmonizacao entre os laboratorios foi avaliado atraves do calculo dos coeficientes de variacao interlaboratorio meios globais (CV%) por analito e por pais para os 6 niveis. Nao obstante, o estado de padronizacao foi avaliado depois da eliminacao de valores atipicos pelo calculo de recuperacoes medias gerais (%) se comparados com os valores atribuidos por analito por pais para os 6 niveis. Os vieses medios absolutos foram comparados com os vieses (minimos / desejaveis) decorrentes dos criterios de variacao biologica. Para enzimas sericas, os CV interlaboratorio nos laboratorios argentinos oscilaram entre 10 e 22%, em comparacao com 3-6% nos Paises Baixos. Para o acido urico serico, creatinina, glicose e proteinas totais, os CV entre laboratorios variaram entre 4,3 e 13,1% nos laboratorios argentinos, em comparacao com <3,5% nos Paises Baixos para os eletrolitos sericos, os CV interlaboratorios oscilaram entre 1,8 e 3,8% para Na+; 2,9-5,8% para Cl-; 3,8-7,5% para K+; 9,4-10,4% para Ca2+ e 16,2-22,3% para Mg2+ em comparacao com ≤2% (Na+, K+, Cl-, Ca2+) e ≤3% (Mg2+) nos Paises Baixos. As recuperacoes medias em laboratorios argentinos para, p.ex. a creatinina serica, glicose, CK, Ca2+ e Na+ foram 95-119%; 95-104%; 98-102%; 98-102% e 96-100% respectivamente, enquanto que os intervalos de recuperacao min-max. foram 65-155%; 58-126%; 47-132%; 66-132% e 85-115%. Nos Paises Baixos, as recuperacoes medias absolutas foram em geral de 98,9% com um desvio padrao (DE) de 2,0%. A mediana dos vieses medios dos laboratorios argentinos oscilou entre -2,9 e 18,2%; -3,1 - 2,6%; -3,3 - 0,5%; -1,1 - 3,8% e -4,3-0% para creatinina serica, glicose, CK, Ca2+ e Na+. Nos Paises Baixos, as medias / medianas em geral foram de 1,1% (DE=2,0%). O intercambio dos valores atribuidos aos materiais EQA, comutaveis, foi de grande ajuda para a harmonizacao e padronizacao dos ensaios medicos na Argentina e para revelar o potencial futuro de harmonizacao e padronizacao. Esses resultados demonstram as claras que a rastreabilidade metrologica dos resultados dos testes na Argentina esta de acordo com o esperavel; a dispersao entre laboratorios ainda e muito grande e deveria ser melhorada.


Subject(s)
Humans , Reference Standards , Clinical Chemistry Tests , Clinical Chemistry Tests/methods , Laboratories , Physicians , Uric Acid , Weights and Measures , Proteins , Bias , Chemistry, Clinical , Creatinine , State , Electrolytes , Enzymes , Methodology as a Subject , Glucose
2.
Acta bioquím. clín. latinoam ; 50(3): 469-487, set. 2016. ilus, graf, tab
Article in Spanish | LILACS | ID: biblio-837625

ABSTRACT

Objetivos: Evaluar criticamente las implicaciones clinicas de la utilizacion del perfil lipidico sin ayuno en lugar de perfiles de lipidos con ayuno y proporcionar orientacion para la elaboracion de informes de laboratorio sobre perfiles lipidicos anormales con ayuno y sin ayuno. Metodos y Resultados: Abundantes datos observacionales, en los que perfiles lipidicos medidos aleatoriamente sin ayuno se han comparado con perfiles lipidicos determinados en condiciones de ayuno, indican que las variaciones medias maximas de 1-6 h despues de ingestas habituales no son clinicamente significativas [+0,3 mmol/L (+26 mg/dL) para trigliceridos; -0,2 mmol/L (-8 mg/dL) para colesterol total; -0,2 mmol/L (-8 mg/dL) para colesterol-LDL; +0,2 mmol/L (+8 mg/dL) para colesterol de remanentes calculado; -0,2 mmol/L (-8 mg/dL) para el colesterol no-HDL calculado]; las concentraciones de colesterol-HDL, apolipoproteina A1, apolipoproteina B, y lipoproteina(a) no se ven afectados por el estado de ayuno/ no ayuno. Ademas, las concentraciones en ayunas y sin ayuno varian de manera similar con el tiempo y son comparables en la prediccion de la enfermedad cardiovascular. Para mejorar el cumplimiento del paciente con las condiciones para la determinacion del perfil lipidico, por lo tanto, se recomienda el uso rutinario de los perfiles lipidicos sin ayuno, mientras que se puede considerar la toma de muestra en ayunas cuando los trigliceridos sin ayuno son >5 mmol/L (440 mg/dL). Para las muestras sin ayuno, los informes de laboratorio deberian marcar como concentraciones anormales a trigliceridos ≥2 mmol/L (175 mg/dL), colesterol total ≥5 mmol/L (190 mg/dL), colesterol-LDL ≥3 mmol/L (115 mg/dL), colesterol remanente calculado ≥0,9 mmol/L (35 mg/dL), colesterol no-HDL calculado ≥3.9 mmol/L (150 mg/dL), HDL colesterol ≤1 mmol/L (40 mg/dL), apolipoproteina A1 ≤1,25 g/L (125 mg/dL), apolipoproteina B ≥1,0 g/L (100 mg/dL), y lipoproteina(a) ≥50 mg/dL (percentil 80); para muestras con ayuno, las concentraciones anormales corresponden a trigliceridos ≥1,7 mmol/L (150 mg/dL). Aquellas concentraciones que ponen en peligro la vida requieren derivacion inmediata debido al riesgo de pancreatitis cuando los trigliceridos son >10 mmol/L (880 mg/dL), de hipercolesterolemia familiar homocigotica cuando el colesterol-LDL es >13 mmol/L (500 mg/dL) o hipercolesterolemia familiar heterocigota cuando el colesterol-LDL es >5 mmol/L (190 mg/dL), y debido al riesgo cardiovascular muy alto cuando la lipoproteina(a) es >150 mg/dL (percentil 99). Conclusiones: Recomendamos la utilizacion de rutina de muestras de sangre sin ayuno para la evaluacion del perfil lipidico plasmatico. Los informes de laboratorio deberian marcar resultados anormales basandose en valores de corte deseables. Las determinaciones con ayuno y sin ayuno deben ser complementarias, pero no se excluyen mutuamente.


Aims: To critically evaluate the clinical implications of the use of non-fasting rather than fasting lipid profiles and to provide guidance for the laboratory reporting of abnormal non-fasting or fasting lipid profiles. Methods and Results: Extensive observational data, in which random non-fasting lipid profiles have been compared with those determined under fasting conditions, indicate that the maximal mean changes at 1-6 h after habitual meals are not clinically significant [+0.3 mmol/L (26 mg/dL) for triglycerides; -0.2 mmol/L (8 mg/dL) for total cholesterol; -0.2 mmol/L (8 mg/dL) for LDL cholesterol; +0.2 mmol/L (8 mg/dL) for calculated remnant cholesterol; -0.2 mmol/L (8 mg/dL) for calculated non-HDL cholesterol]; concentrations of HDL cholesterol, apolipoprotein A1, apolipoprotein B, and lipoprotein(a) are not affected by fasting/nonfasting status. In addition, non-fasting and fasting concentrations vary similarly over time and are comparable in the prediction of cardiovascular disease. To improve patient compliance with lipid testing, we therefore recommend the routine use of non-fasting lipid profiles, whereas fasting sampling may be considered when non-fasting triglycerides are >5 mmol/L (440 mg/dL). For nonfasting samples, laboratory reports should flag abnormal concentrations as triglycerides ≥2 mmol/L (175 mg/dL), total cholesterol ≥5 mmol/L (190 mg/dL), LDL cholesterol ≥3 mmol/L (115 mg/dL), calculated remnant cholesterol ≥0.9 mmol/L (35 mg/dL), calculated non-HDL cholesterol ≥3.9 mmol/L (150 mg/dL), HDL cholesterol ≤1 mmol/L (40 mg/dL), apolipoprotein A1 ≤1.25 g/L (125 mg/dL), apolipoprotein B ≥1.0 g/L (100 mg/dL), and lipoprotein(a) ≥50 mg/dL (80th percentile); for fasting samples, abnormal concentrations correspond to triglycerides ≥1.7 mmol/L (150 mg/dL). Life-threatening concentrations require separate referral for the risk of pancreatitis when triglycerides are >10 mmol/L (880 mg/dL), for homozygous familial hypercholesterolemia when LDL cholesterol is >13 mmol/L (500 mg/dL), for heterozygous familial hypercholesterolemia when LDL cholesterol is >5 mmol/L (190 mg/dL), and for very high cardiovascular risk when lipoprotein(a) >150 mg/dL (99th percentile). Conclusions: We recommend that non-fasting blood samples be routinely used for the assessment of plasma lipid profiles. Laboratory reports should flag abnormal values on the basis of desirable concentration cutpoints. Non-fasting and fasting measurements should be complementary but not mutually exclusive.


Subject(s)
Lipid Metabolism , Observational Studies as Topic , Translations